Hydro-split INVISIBLE Version
Invisible, uncased indoor unit for your Hydro-Split system.
WiSAN-YME 1 S + HQCN-NEE 1 IC A WiSAN-PME 1 S + HQCN-NEE 1 IC  
Hydro-split INVISIBLE Invisible efficiency at work
Invisible efficiency at work

Inside wall installation: invisible efficiency at work.
Easier and cheaper installation ever: just need a plumber.

Internal structure of the product Hydro-split invisible version.
More options, less space

Compact design and intelligent layout of components for extra accessories requiring no extra space.

 

Comfortably from your sofa

Manage your ideal temperature directly via your smartphone, even while relaxing on your sofa.

Phone with hid-connect application, Manage your ideal temperature directly via your smartphone

The perfect size is what you want

Choose the hot water volume you need: 150 to 300 litres to better suit your needs.

Free Cooling / Heating
Free Cooling / Heating
Provides Cooling / Heating for free (on certain conditions)
DHW
DHW
Produces Domestic Hot Water
Contemporaneity  (Hybrid version)
Contemporaneity (Hybrid version)
Produces Heating and Domestic Hot Water at the same time
Silent
Silent
For more silent operation
Free Cooling / Heating
Free Cooling / Heating
Provides Cooling / Heating for free (on certain conditions)
DHW
DHW
Produces Domestic Hot Water
Contemporaneity  (Hybrid version)
Contemporaneity (Hybrid version)
Produces Heating and Domestic Hot Water at the same time
Silent
Silent
For more silent operation

Technical Synthesis

Dimensions Indoor Unit (Length x Height x Depth)
From 950x2200x360 mm
Dimensions of Outdoor Unit (Length x Height x Depth)
From 1295x7127x400 mm
Heating Efficiency Class (Medium Climate)
A+++ (Water 35 °C)
A++ (Water 55 °C)
Consecutive showers available
from 3 to 4
Home surface range
from 42 to 110 m²
Sound level indoor unit
from 41 dB(A) (like a refrigerator)

Complete your system

Hydronic modules are designed to simplify installation, reducing both the operations and the expertise required, so you can immediately have your ideal climate in combination with a packaged heat pump.

EDGE EVO 2.0 - EXC: Complete your system with a packaged heat pump for heating, cooling and domestic hot water production EDGE EVO 2.0 - EXC

Complete your plant with a packaged heat pump EDGE EVO 2.0 - EXC

EDGE F: Complete your system with a packaged heat pump for heating, cooling and domestic hot water with refrigerant R-290

Complete your plant with a packaged heat pump with refrigerant R-290

Looking for Support?
Contact us: a Clivet consultant will answer your queries.

Discover our alternative solutions

HYDRO-SPLIT version BOX: WISAN-YME 1 S + HQCN-NEE 1 BC A WISAN-PME 1 S + HQCN-NEE 1 BCÈ piccola ma potente
Hydro-split BOX Version

Wall-mounted indoor unit for your Hydro-Split system.

WISAN-YME 1 S + HQCN-NEE 1 BC A WISAN-PME 1 S + HQCN-NEE 1 BC

HYDRO-SPLIT version MINI, wall-mounted indoor unit
HYDRO-SPLIT MINI version

Wall-mounted indoor unit with DHW tank for Hydro-split systems

WISAN-YME 1 S + HQCN-NEE 1 MC A - WISAN-PME 1 S + HQCN-NEE 1 MC

Hydro-Split TOWER Version: WISAN-YME 1 S + HQCN-NEE 1 TC A WISAN-PME 1 S + HQCN-NEE 1 TC A
Hydro-Split TOWER Version

Indoor hydronic unit with base with DHW tank for Hydro Split systems

WISAN-YME 1 S + HQCN-NEE 1 TC A WISAN-PME 1 S + HQCN-NEE 1 TC A

Respect distances to be maintained: 500 millimetres front.
Optimised spaces

It is essential to comply with the distances indicated by the green areas to ensure correct operation of the unit. Check or ask one of our consultants to study the best location in your environments.

Technical Specifications

Size
Dimensions Indoor Unit (Length x Height x Depth)
From 950x2200x360 mm
Dimensions of Outdoor Unit (Length x Height x Depth)
From 1295x7127x400 mm
Operating range (outside air)
Operating range in Heating
-25 / 43 °C
Operating range in Cooling
-5 / 43 °C
Seasonal Efficiency
Heating Efficiency Class (Medium Climate)
A+++ (Water 35 °C) A++ (Water 55 °C)
Domestic Hot Water Production
A+ with Withdrawal profle L
Performance
Heating (Outdoor air 7 °C / water 35 °C)
from 4.20 kW to 10.0 kW: COP up to 5.15
Heating (Outdoor air 7 °C / water 35 °C)
from 4.170 kW to 8.00 kW: COP up to 3.20
Cooling (Outdoor air 35 °C / water 18 °C)
from 4.50 kW to 9.90 kW: EER up to 5.50
Water mixed at 40 °C
Up to 188 lt
Dimension
Consecutive showers available
from 3 to 4
Home surface range
from 42 to 110 m²
Sound power
Sound level indoor unit
from 41 dB(A) (like a refrigerator)
Sound level of outdoor unit
from 53 dB(A) (like moderate rain)
Possible combinations
Single-zone system + boiler + instant kit: Heating / DHW
  1. outdoor unit
  2. indoor unit
  3. Condensing boiler
  4. Circuit breaker two-area kit + pump
  5. Medium temperature heating system
  6. DHW recirculation pump
  7. Bypass
  8. Hid-TConnect2 chronothermostat
  9. Receiver / IoT switch SwitchConnect
Single-zone system + boiler + instant kit: Heating / DHW

System elements:

ELFOSUN3: flat-plate solar thermal collector for combination with heating and domestic hot water production systems
ELFOSUN3

Flat-plate solar thermal collector for combination with heating and domestic hot water production systems

F-L / F-XL / FH-XL

CONTROL4 NRG
CONTROL4 NRG

Comfort and energy assistance for Clivet Smart Living

HID-TCONNECT2: CSmart Wi-Fi thermostat makes it possible to monitor your indoor climate via Clivet Home Connect App
HID-TCONNECT

Chronothermostat with temperature control and management via App /Voice control

Looking for Support?
Contact us: a Clivet consultant will answer your queries.

Useful links

Become a Clivet installer
The Clivet Clima Club is a team of selected professionals that represents the flagship of Clivet's installer partners

Our projects

>
>
>
>
>
Looking for Support?
Contact us: a Clivet consultant will answer your queries.